ECLORplus Volume Corrector Information about the gas flow volume is sensed in the pulse outputs with the fuel meter or with the encoder information output.

risk of set up with integrated modem (version only with external electricity provide of your machine)

A simplified Variation of The larger ELCORplus, the ELCOR is built as only one channel EVC with just one RS485/RS232 serial port. An individual battery powers the EVC and an optional embedded modem. The ELCOR is appropriate for cheap jobs where by a reliable, good but potent EVC is demanded. 

ELCOR-ninety four is battery powered Digital corrector, converting the gas volume to generally be flown by means of gas meter to referential disorders of pressure and temperature. For organic fuel calculates the fuel compressibility degree In keeping with ČSN 38 5510. Calculated values of temperature, pressure and working volume and calculated values of standardised volume are stored into machine memory.

Magnetic flow meters encompass a detector plus a converter, While using the basic principle on the detector adopting Faraday's electromagnetic induction law. Faraday's Regulation states that if conductive fluid flows in a very magnetic discipline, an electromagnetic force is generated in proportion on the fluid's flow velocity.

The housing was intended to operate in severe out of doors environments with Licensed IP66 security class.

5 Installation and Commissioning The weld-on fitting should be welded in this type of way that the thermowell is within the vertical placement, or inclined below 45° angle with the vertical axis Along with the cavity up (Fig.

The essential functioning principle of differential pressure flow meters is based to the premise which the pressure fall through the meter is proportional to your sq. in the flow fee. The flow rate is acquired by measuring the pressure differential and extracting the square root.

If you will discover any problems with the Procedure from the product for virtually any purpose, specialized help personnel may very well be contacted.

Gas-volume conversion unit ElCOR-ninety four calculates the lower-frequency volume impulses from turbine, rotary or diaphragmal gasoline meters. It calculates flown functioning volume from amount of impulses and from fuel meter continuous.

Traditionally these kinds of Evaluation operate was carried out working with hand calculation approaches, empirical formulae, nomogram charts as well as knowledge to determine the pumping frequency from the pump and then identify the organic frequency on the piping spans.

eight Metrological Functions Fig. 74 Processing the volumes on the fuel meter revers rotation Observe: When the instrument is about to regard the alter of fuel flow route in the gas meter, it can be done to turn on the counter while in the instrument parameters, where the amount of gas flow is stored in the course of the gas meter return. Webpage a hundred and fifty: Connecting Inputs

ELCORplus ZONE2 has carried out variety "nA" protection together with defense "ic" and can't be Utilized in a Class1Div1 setting.

API674 and API618 are both of those specs issued via the American Petroleum Institute that include the assessment of piping devices for pressure pulsation and mechanical reaction (modal vibration). High Pressure Flow Meter

Report this page